X940kVADSPLCD3P

Tuncmatik HI-TECH Ultra X9 40kVA DSP LCD 3P/3P, Online, without batteries

Rating: Not Rated Yet
ManufacturerTuncmatik
Availability:in stock 110 item(s)
Code:84712
Warranty:            24  Months
114763 Lei
  (with VAT)
UPS Tuncmatik HI-TECH Ultra X9 40 kVA DSP LCD 3P/3P Online, without batterieshttp://www.tuncmatik.com/ru/product/overview/hi-tech-ultra-40-kva.htmlInputPhase : 3 phase 4 wire and groundNominal voltage : 380/400/415 VACVoltaj range : 208~478 VACFrequency range : 45-55Hz de 50Hz/54-66Hz at 60Hz (auto sensing)Current THDi : ?3% (100% nonlinear load)Bypass voltage range : Max. voltagePower factor : ?0.99OutputPhase : 3 phase 4 wire and groundNominal voltage : 380/400/415 VAC,Power factor : 0.9Voltage regulation : ± 1%Frequency Normal mode : ± 1%, ± 2%, ± 4%, ± 5%, ± 10% of the rated frequency (optional)Frequency Battery mode : (50/60±0.2%) HzCrest factor : 3/1THD : ?2% with linear load, ?5% with non linear loadEfficieny : 94%BatteryVoltage : Standard unit.±240Vdc (4x20 ad. 12V7Ah) Long run unit optional voltage.±192V/±204V/±216V/±240VDC (32/34/36/38/40pcs)Charge current (A) (charge current can be set according to battery capacity installed : Long run unit. Max. current 10ATransfer time : Utility to battery. 0ms; Utility to bypass. 0msProtectionOverload AC mode : Loads ?110%. last 60min, ?125%. last 10min, ?150%. last 1min, >150% change to bypass immediatelyOverload Battery mode : Loads ?110%. last 10min, ?125%. last 1min, ?150%. >150% shut down UPS immediatelyOverload Bypass mode : Breaker 80AShort circuit 164 peak : Over temperature Line mode : Switch to bypass, Backup modeBattery low Alarm and switch off : Self-diagnostic Upon power on and software control : EPO (optional) Shut down UPS immediately : Battery Advanced battery management : Noise suppression Complies with EN62040-2Indicators & AlarmStatus LED & LCD : Line mode, Bypass mode, Battery low, Battery bad, Overload & UPS faultLCD panel : Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage & Inner temperatureAudible & Visual : Line failure, Battery low, Overload, System faultManagementOperating systems : Windows® 98/2000/2003/XP/Vista/2008, Windows? 7/8, Linux, MA
* Fotografia are caracter informativ. Specificaţiile sau preţul pot fi modificate de către producător, furnizor fără preaviz sau pot conţine erori de operare. Pentru detalii suplimentare, contactați-ne prin e-mail sau telefon.

Description

UPS Tuncmatik HI-TECH Ultra X9 40 kVA DSP LCD 3P/3P Online, without batterieshttp://www.tuncmatik.com/ru/product/overview/hi-tech-ultra-40-kva.htmlInputPhase : 3 phase 4 wire and groundNominal voltage : 380/400/415 VACVoltaj range : 208~478 VACFrequency range : 45-55Hz de 50Hz/54-66Hz at 60Hz (auto sensing)Current THDi : ?3% (100% nonlinear load)Bypass voltage range : Max. voltagePower factor : ?0.99OutputPhase : 3 phase 4 wire and groundNominal voltage : 380/400/415 VAC,Power factor : 0.9Voltage regulation : ± 1%Frequency Normal mode : ± 1%, ± 2%, ± 4%, ± 5%, ± 10% of the rated frequency (optional)Frequency Battery mode : (50/60±0.2%) HzCrest factor : 3/1THD : ?2% with linear load, ?5% with non linear loadEfficieny : 94%BatteryVoltage : Standard unit.±240Vdc (4x20 ad. 12V7Ah) Long run unit optional voltage.±192V/±204V/±216V/±240VDC (32/34/36/38/40pcs)Charge current (A) (charge current can be set according to battery capacity installed : Long run unit. Max. current 10ATransfer time : Utility to battery. 0ms; Utility to bypass. 0msProtectionOverload AC mode : Loads ?110%. last 60min, ?125%. last 10min, ?150%. last 1min, >150% change to bypass immediatelyOverload Battery mode : Loads ?110%. last 10min, ?125%. last 1min, ?150%. >150% shut down UPS immediatelyOverload Bypass mode : Breaker 80AShort circuit 164 peak : Over temperature Line mode : Switch to bypass, Backup modeBattery low Alarm and switch off : Self-diagnostic Upon power on and software control : EPO (optional) Shut down UPS immediately : Battery Advanced battery management : Noise suppression Complies with EN62040-2Indicators & AlarmStatus LED & LCD : Line mode, Bypass mode, Battery low, Battery bad, Overload & UPS faultLCD panel : Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage & Inner temperatureAudible & Visual : Line failure, Battery low, Overload, System faultManagementOperating systems : Windows® 98/2000/2003/XP/Vista/2008, Windows? 7/8, Linux, MACInterface : RS 485, USB, Paralel (Optional), Dry contact, Intelligent slot, SNMP adapter (Optional), Relay card (Optional)Dimensions & WeightD x G x Y (mm) : 828 x 250 x 868Weight(kg) : 73

Reviews

Last Reviews

There are yet no reviews for this product.
First: Rate the product. Please select a rating between 0 (poorest) and 5 stars (best). Rating:
Characters written:
Please write your (short) review....(min. 0, max. 2000 characters)
Important! When publishing reviews and comments you agree to terms and conditions of our website!

Brief comment

Add comment


Security code Refresh
Important! When publishing reviews and comments you agree to terms and conditions of our website!
Back to: UPS (Uninterruptible Power Supply)